-
SunGuard XLPE Aluminum, Photovoltaic Wire 2kV, 90掳C
-sunguard-xlpe-aluminum-photovoltaic-wire-2kv-90-c
-
SunGuard XLPE Aluminum, Photovoltaic Wire 2 kV, 90掳C - PHYSICAL PROPERTIES
Applications
Single conductor, sunlight-resistant, photovoltaic wire rated 90 ºC wet or 105ºC dry 2000V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70. For use in free air, raceways or direct burial in accordance with NEC.
Construction
Conductor:8 7m视频 thru 1000 kcmil compact aluminum (8000 series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE), black
Options:- Colored phase ID stripes available on request
- Multiplexing available on request
- UL 1581 VW-1 compliance available on request
- Rated 90ºC wet and dry
- Deformation-resistant at high temperatures
- Excellent moisture resistance, exceeds UL 44
- Stable electrical properties over a broad temperature range
- Excellent resistance to crush and compression cuts
- Resistant to most oils and chemicals
- UV/sunlight-resistant
- Meets cold bend test at -40 ºC
- ASTM B800 - 05(2011) Standard Specification for 8000 Series Aluminum Alloy Wire for Electrical Purposes - Annealed and Intermediate Tempers
- ASTM B801 - 07(2012) Standard Specification for Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation
- ASTM B836 - 00(2011) Standard Specification for Compact Round Stranded Aluminum Conductors Using Single Input Wire Construction
- UL 4703 Type PV
- National Electrical Code (NEC)
- ICEA S-95-658/NEMA WC70
- UL 44 Type RHH or RHW-2
Other Compliances
- EPA 40 CFR, Part 261 for leachable lead content per TCLP
- OSHA Acceptable
- RoHS Compliant, Sun Res, Gas and Oil Resistant II
Option
Packaging:
UL 1581 VW-1 compliance available on request
19 strand conductors available on request
Material cut to length and shipped on non-returnable wood reels
AA8000 Maximum Electrical Resistivity Temperature 20℃ 7m视频 size Ω/1000ft Ω/1000m 8 1.07 3.515 7 0.8495 2.787 6 0.674 2.211 5 0.5346 1.754 4 0.4238 1.39 3 0.3361 1.103 2 0.2665 0.8745 1 0.2113 0.6934 1/0 0.1676 0.5498 2/0 0.1329 0.4361 3/0 0.1055 0.3459 4/0 0.836 0.2743 250kmil 0.07076 0.2322 300 0.05897 0.1935 350 0.05054 0.1659 400 0.04423 0.145 450 0.03931 0.1289 500 0.03537 0.1161 550 0.03216 0.1055 600 0.02948 0.09673 700 0.02527 0.08291 750 0.02358 0.07738 800 0.02211 0.07254 900 0.01966 0.06448 1000 0.01769 0.05804
-
SunGuard XLPE Aluminum, Photovoltaic Wire 2 kV, 90掳C - ELECTRICAL PROPERTIES
Applications
Single conductor, sunlight-resistant, photovoltaic wire rated 90 ºC wet or 105ºC dry 2000V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70. For use in free air, raceways or direct burial in accordance with NEC.
Construction
Conductor:8 7m视频 thru 1000 kcmil compact aluminum (8000 series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE), black
Options:- Colored phase ID stripes available on request
- Multi-plexing available on request
- UL 1581 VW-1 compliance available on request
- Rated 90ºC wet and dry
- Deformation-resistant at high temperatures
- Excellent moisture resistance, exceeds UL 44
- Stable electrical properties over a broad temperature range
- Excellent resistance to crush and compression cuts
- Resistant to most oils and chemicals
- UV/sunlight-resistant
- Meets cold bend test at -40 ºC
- ASTM B800 - 05(2011) Standard Specification for 8000 Series Aluminum Alloy Wire for Electrical Purposes - Annealed and Intermediate Tempers
- ASTM B801 - 07(2012) Standard Specification for Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation
- ASTM B836 - 00(2011) Standard Specification for Compact Round Stranded Aluminum Conductors Using Single Input Wire Construction
- UL 4703 Type PV
- National Electrical Code (NEC)
- ICEA S-95-658/NEMA WC70
- UL 44 Type RHH or RHW-2
Other Compliances
- EPA 40 CFR, Part 261 for leachable lead content per TCLP
- OSHA Acceptable
- RoHS Compliant, Sun Res, Gas and Oil Resistant II
Option
Packaging:
UL 1581 VW-1 compliance available on request
19 strand conductors available on request
Material cut to length and shipped on non-returnable wood reels
AA8000 Maximum Electrical Resistivity Temperature 20℃ 7m视频 size Ω/1000ft Ω/1000m 8 1.07 3.515 7 0.8495 2.787 6 0.674 2.211 5 0.5346 1.754 4 0.4238 1.39 3 0.3361 1.103 2 0.2665 0.8745 1 0.2113 0.6934 1/0 0.1676 0.5498 2/0 0.1329 0.4361 3/0 0.1055 0.3459 4/0 0.836 0.2743 250kmil 0.07076 0.2322 300 0.05897 0.1935 350 0.05054 0.1659 400 0.04423 0.145 450 0.03931 0.1289 500 0.03537 0.1161 550 0.03216 0.1055 600 0.02948 0.09673 700 0.02527 0.08291 750 0.02358 0.07738 800 0.02211 0.07254 900 0.01966 0.06448 1000 0.01769 0.05804