TOWERGUARD® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV
b-towerguard-2000-b-xlp-al-2kv-rhh-rhw-2
-
TOWERGUARD® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV
Applications
- For use from the lower control box at the base of the wind power tower and out to the step-up transformer through conduit
- For use in free air, raceways or direct burial in accordance with NEC.
- Industrial environments where superior insulation toughness and chemical resistance is required
- Maximum operating temperature not to exceed 90 ºC in wet or dry locations
Conductor: 8 7mÊÓƵ thru 1000 kcmil compacted aluminum ACM (AA-8000 Series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE) - Black
Print: TOWERGUARD 2000® XLP 7mÊÓƵ/KCMIL TYPE RHH/RHW-2 SR (UL) 2000V (MM/YYYY) SEQUENTIAL FOOTAGE MARK
Compliances- National Electric Code (NEC)
- UL 44 Stranded for rubber-insulated wires and cables
- ICEA S-95-685/NEMA WC70
- UL listed as Type RHH/RHW-2
- OSHA acceptable
- Rated at 90 ºC wet or dry
- UV resistant - black is marked SR
- Excellent electrical, thermal and physical properties
- Excellent resistance to moisture
- Excellent resistance to crush, compression cuts and heat deformation
Colors optional, to order.
All produced or cut-to-order material will be shipped on non-returnable wooden reels unless specifically requested -
TOWERGUARD® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV - CT Rated
Applications
- For use from the lower control box at the base of the wind power tower and out to the step-up transformer through conduit
- For use in free air, raceways or direct burial in accordance with NEC.
- Industrial environments where superior insulation toughness and chemical resistance is required
- Maximum operating temperature not to exceed 90 ºC in wet or dry locations
Conductor: 8 7mÊÓƵ thru 1000 kcmil compacted aluminum ACM (AA-8000 Series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE) - Black
Print: TOWERGUARD 2000® XLP 7mÊÓƵ/KCMIL TYPE RHH/RHW-2 SR (UL) 2000V (MM/YYYY) SEQUENTIAL FOOTAGE MARK [Sizes 1/0 7mÊÓƵ and larger include the "CT" marking]
Compliances- National Electric Code (NEC)
- UL 44 Stranded for rubber-insulated wires and cables
- "CT" for 1/0 7mÊÓƵ and larger in accordance with NEC
- ICEA S-95-685/NEMA WC70
- UL listed as Type RHH/RHW-2
- OSHA acceptable
- Rated at 90 ºC wet or dry
- UV resistant - black is marked SR
- Excellent electrical, thermal and physical properties
- Excellent resistance to moisture
- Excellent resistance to crush, compression cuts and heat deformation
Colors optional, to order.
All produced or cut-to-order material will be shipped on non-returnable wooden reels unless specifically requested