Duplex Service Drop Aluminum Conductor
duplex-service-drop-br-aluminum-conductor
-
Duplex Service Drop Aluminum Conductor - AAC Neutral Messenger
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 ºC maximum.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC neutral messenger.
Standards- B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
- B-231 Aluminum Conductors, Concentric-Lay-Stranded.
- B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
- B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
- B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
- Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
-
Duplex Service Drop Aluminum Conductor - ACSR Neutral Messenger
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 ºC maximum.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand ACSR neutral messenger.
Standards- B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
- B-231 Aluminum Conductors, Concentric-Lay-Stranded.
- B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
- B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
- B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
- Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
-
Duplex Service Drop - Aluminum Conductor - AAAC 6201 Alloy Neutral Messenger
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 ºC maximum.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand 6201 alloy neutral messenger.
Standards- B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
- B-231 Aluminum Conductors, Concentric-Lay-Stranded.
- B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
- B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
- B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
- Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
-
PACKAGING INFORMATION: Duplex Service Drop Aluminum Conductor
Packaging Information: Duplex Service Drop Aluminum Conductor CODE WORD ALUMINUM
CONDUCTORSSTANDARD PACKAGE SIZES PHASE
SIZE AND STRANDINGNEUTRAL
SIZE AND STRANDINGLENGTH WEIGHT
PE
(lbs)WEIGHT
XLP
(lbs)REEL
SIZEAAC Messenger Collie 6-7 6-7 500 32 33 Coil 2,800 179 185 NRC 30.18 Spaniel 4-7 4-7 500 48 50 Coil 2000 192 198 NRC 30.18 ACSR Messenger Shepherd 6-7 6-6/1 1,000 75 77 Coil 3,300 248 254 NRC 38.18 Terrier 4-7 4-6/1 500 58 59 Coil 2,000 230 234 NRC 30.18 Aluminum Alloy 6201-T81 Messenger Vizsla 6-7 6-7 500 34 35 Coil 2,800 190 196 NRC 30.18 Whippet 4-7 4-7 500 52 53 Coil 2,000 206 210 NRC 30.18