Loose Tube Fiber Optic Cable for Direct Burial
les-loose-tube-fiber-optic-cable-for-direct-burial
-
Fiber Optic - Loose Tube - for Direct Burial (Polyethylene Duct)
Application
Single jacket loose tube cable with a dielectric central strength member, reinforced with glass yarns and polyethylene jacket, designed for outdoor applications, for direct installations in duct. The cable is supplied in UV resistant high density polyethylene (HDPE) duct.ConstructionÌý
Up to 12 optical fibers are enclosed in a polybutylene terephthalate (PBT) tubes.
Up to 24 tubes are stranded around jacketed dielectric central member together with PE fillers to form the cable core.
The fibers and tubes are color coded for easy identification.
All the interstices in the cable core are filled with a water blocking materials to prevent water penetration. Water swelling glass yarns are laid over the cable core to serve as peripheral dielectric strength members.
A polyethylene jacket extruded over the glass yarns provides the final cable shape and protection. A ripcord is provided under the jacket to facilitate its removal.
The cable is inserted into UV resistant high density polyethylene duct for wide range of uses including extreme temperatures, abrasive and high tension applications in underground installations.
Cable Nominal Dimensions and Weight
FIBER
COUNT2-60
61-72
73-96
97-120
121-144
145-216
217-240
241-288
Cable
OuterÌý
Diameterinch
0.4
0.42
0.49
0.56
0.62
0.61
0.64
0.71
mm
10.1
10.7
12.5
14.1
15.7
15.4
16.2
18
Cable
Weightlb/kft
47
53
69
97
112
97
109
134
kg/km
70
79
103
145
166
145
162
200
Cable HandlingÌýÌý
Minimum bend radius withÌýload
Minimum bend radius with no load
Minimum bend radius, storage coilsÌý
Maximum rated cable load (MRCL)Ìý
Maximum long term load15 x ODÌý
10 x OD
10 x OD
600 lbs (2700 N)
180 lbs (800N)
ÌýTemperature RangeÌýÌý
Ìý
Installation
Operation
StorageÌý-300C to 600C (-220F to 1400F)
-600C to 700C (-760F to 1580F)
-400C to 750C (-400F to 1670F)Fiber CharacteristicsÌý
Ìý
Type
Single mode
Multi mode
PHYSICAL Characteristics
Ìý
Ìý
50/125
62.5/125
Core Diameter
µ³¾
Ìý
50.0 ± 2.5
50.0 ± 2.5
Clad Diameter
µ³¾
125.0 ± 0.7
125.0 ± 1.0
125.0 ± 1.0
Core/Clad Concentricity Error (Offset)
µ³¾
≤ 0.5,<0.2 typical
≤ 1.0
≤ 1.0
Coating diameter
µ³¾
235-245
245 ± 10
245 ± 10
Tensile proof test
kpsi
100
100
100
OPTICAL CHARACTERISTICS
Ìý
Ìý
Ìý
Ìý
Attenuation for Wavelength at 1310 nm
dB/km
≤0.34 (max), ≤0.32 typical
Ìý
Ìý
Attenuation for Wavelength at 1550 nm
dB/km
≤0.21 (max), ≤0.19 typical
Ìý
Ìý
Attenuation for Wavelength at 850 nm
dB/km
Ìý
≤ 2.3
≤ 0.9
Attenuation for Wavelength at 1300 nm
dB/km
Ìý
≤ 0.6
≤ 0.6
Zero Dispersion Wavelength (λ0)
Nm
1302-1322
1295-1340
1320-1365
MODE FIELD DIAMETER
Ìý
Ìý
Ìý
Ìý
for wavelength 1310 nm
µ³¾
9.2 ± 0.4
Ìý
Ìý
for wavelength 1550 nm
µ³¾
10.4 ± 0.5
Ìý
Ìý
Cut-off wavelength (λcc)
nm
≤ 1260
Ìý
Ìý
Fibers and Tubes Color-Code per TIA/EIA 598A
FIBER
NO.1
2
3
4
5
6
7
8
9
10
11
12
COLOR
Blue
Orange
Green
Brown
Slate
White
Red
Black
Yellow
Violet
Rose
Aqua
Polyethylene Duct Characteristics
General specification:The duct is manufactured from virgin high density polyethyleneThe ducts are supplied with smooth walls and come either in orange color or in black with 3 orange stripesThe duct is capable of being coiled in continuous lengths, transported, stored outdoors and subsequently uncoiled for installation – without affecting its properties or performanceThe duct performs in underground and above-ground installation an ambient temperature range of minus 300F to 1300FThe duct specified for areal installations is ultraviolet light-resistant by UV light stabilizer protecting the duct for a minimum of 12 months in direct sunlightThe duct is bent to a minimum (supported) radius of 10 outer diameters
Tests on finishing duct are performed in accordance with:- ASTM D3035 Polyethylene Plastic Pipe Based on Controlled Outside DiameterÌý
- ASTM D1248 Polyethylene Plastics Molding and Extrusion Materials (Type III, Class A, B or C, Category 5, grade P34)
- ASTM D1693 Environmental Stress Cracking of Ethylene Plastics (Cond. B, F20/96 HRS)
- ASTM D1238 Flow Rates of Thermoplastics by extrusion Plastometer
- ASTM D638 Tensile properties of Plastics
- ASTM D3350 Polyethylene Plastic Pipe and Fitting Materials (Cell #335440)
- NEMA TC 7 Smooth-wall Coilable Polyethylene Electrical Plastic Duct