Covered Line Wire Alloy 6201 Aluminum Conductor
Covered AL Line Wire Weatherproof
Applications
Covered Line Wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
Construction
Conductors are aluminum alloy 1350-H19, 6201-181, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked polyethylene (XLP).
Standards
Covered Line Wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
Construction
Conductors are aluminum alloy 1350-H19, 6201-181, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked polyethylene (XLP).
Standards
- ASTM B-230 - Aluminum 1350-H19 Wire for Electrical Purposes.
- ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
- ASTM B-1248 - Polyethylene Plastics Molding and Extrusion Materials.
- ASTM C-8.35 - Specifications for Weather-Resistant Polyethylene-Covered Wire and Cable.
- ICEAS-61-402
- NEMA PUB NO. WC 5-1973 - Standards Publication Thermoplastic insulated Wire and Cable for the Transmission and Distribution of Electrical Energy.
- The code words as given apply to conventional polyethylene line wire.
- For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent.
- Ampacity ratings based on 75 ºC conductor temperature, 25 ºC ambient temperature elevation - sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal resistivity of covering -3ºC-Cm2/Watt-CM. Wind speed 2ft/sec in sun.
- To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Unit of Measure
Items |
/Asset/AL-Weatherproof-Line-Wire.png Hornbeam Covered Line Wire Alloy 6201 Aluminum Conductor |
/Asset/AL-Weatherproof-Line-Wire.png Linden Covered Line Wire Alloy 6201 Aluminum Conductor |
/Asset/AL-Weatherproof-Line-Wire.png Oilnut Covered Line Wire Alloy 6201 Aluminum Conductor |
/Asset/AL-Weatherproof-Line-Wire.png Waterash Covered Line Wire Alloy 6201 Aluminum Conductor |
/Asset/AL-Weatherproof-Line-Wire.png Shellbark Covered Line Wire Alloy 6201 Aluminum Conductor |
|||||
Size (7mÊÓƵ or kcmil) |
N/A 4 | N/A 2 | N/A 1/0 | N/A 2/0 | N/A 3/0 | |||||
Strand | N/A 7/w | |||||||||
Insulation Thickness (mils) |
N/A 30 mls | N/A 45 mls | N/A 60 mls | N/A 60 mls | N/A 60 mls | |||||
Outside Diameter |
N/A .310 Inches | N/A .406 Inches | N/A .518 Inches | N/A .567 Inches | N/A .622 Inches | |||||
Rated Breaking Strength |
N/A 1480 Lbs | N/A 2520 Lbs | N/A 4010 Lbs | N/A 4850 Lbs | N/A 6110 Lbs | |||||
Weight Per (lb/1000 ft) XLP |
N/A 62.1 Lbs | N/A 96.1 Lbs | N/A 166.1 Lbs | N/A 203.3 Lbs | N/A 249.4 Lbs | |||||
Weight (lb/1000 ft) Poly |
N/A 60.1 Lbs | N/A 93.3 Lbs | N/A 160.0 Lbs | N/A 196.4 Lbs | N/A 241.4 Lbs | |||||
Ampacity XLP |
N/A 145 Amps | N/A 190 Amps | N/A 250 Amps | N/A 290 Amps | N/A 335 Amps | |||||
|