Applications
For use in heavy-duty services as power supply cable, AC systems (grounded and ungrounded), mobile and portable electrical equipment, motor and battery leads. For 2 conductor cables use on DC or AC single phase systems where no grounding is required, or on DC systems with one conductor for grounding. For 4 conductor cables, use on two or three phase AC systems with one conductor used for grounding. For 5 conductor cables, use in applications where separating the system neutral from the frame ground is required.

Construction
  • Conductor is 8 - 500 MCM fully annealed stranded bare copper.
  • Insulation is premium grade color coded 90ºC EPDM.
  • Jacket is 90 ºC Black CPE+ with temperature range of -40 ºC to +90 ºC .
  • Jacket is Indent printed for easy identification (successive footage printing available).
  • Jacket marking is TYPE W PORTABLE POWER CABLE 2000V 90ºC DRY 75 ºC WET SUN RES (UL) - PK(#) MSHA.
  • Designed to withstand severe environmental conditions.
  • Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals.
  • Rope lay stranding for maximum flex life with excellent impact resistance and cable core bound for superior flexibillity and toughness.
  • Suitable for continuous submersion in water.
  • Lengths cut to order.
Standards
ICEA S-75-381 NEMA WC-58 UL TYPE W and MSHA approved.

Notes
  • These ampacities are based on a conductor temperature of 90ºC and an ambient air temperature of 40 ºC per ICEA PUB-S-75-381 NEMA WC0-8. For ampacities per National Electrical Code requirements, refer to the latest NEC edition.
  • Shipping tolerance +/- 10%
  • Heavy-duty neoprene jacket optional.
  • Succesive footage printing available.
Unit of Measure
Items
Image

Type W Round Multi-Conductor 90°C UL 600V/2kV

Image

Type W Round Multi-Conductor 90°C UL 600V/2kV

Image

Type W Round Multi-Conductor 90°C UL 600V/2kV

Image

Type W Round Multi-Conductor 90°C UL 600V/2kV

Image

Type W Round Multi-Conductor 90°C UL 600V/2kV
Number
of
Conductors
N/A 2
Size
(7mÊÓƵ or kcmil)
N/A 8 N/A 6 N/A 4 N/A 2 N/A 1
Conductor
Stranding
N/A 133 N/A 259 N/A 259 N/A 259 N/A 259
Nominal
Thickness
of
Insulation
(Inches)
N/A 0.060 N/A 0.060 N/A 0.060 N/A 0.060 N/A 0.08
Nominal
Thickness of
Insulation
(mm)
N/A 1.52 N/A 1.52 N/A 1.52 N/A 1.52 N/A 2.03
Nominal
O.D.
(Inches)
N/A 0.790 N/A 0.910 N/A 1.060 N/A 1.250 N/A 1.440
Nominal
O.D.
(mm)
N/A 20.07 N/A 23.11 N/A 26.92 N/A 31.75 N/A 36.58
Current
Amps
N/A 72 N/A 95 N/A 127 N/A 167 N/A 191
Weight
(lb/1000 ft)
N/A 365 Lbs N/A 510 Lbs N/A 700 Lbs N/A 1015 Lbs N/A 1490 Lbs