Type MP-GC (Mine Power Feeder)
type-mp-gc-mine-power-feeder
-
Type MP-GC 3-Conductor - EPR/CPE or XLP/CPE 5kV) 100% Insulation Level (Grounded) 90掳C
Applications
This cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for non-flexing service.
Construction- Conductor is stranded annealed copper enveloped in a strand shield.
- Insulation is Ethylene Propylene Rubber (EPR) or Cross Linked Polyethylene (XLPE).
- Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round.
- A single faced rubber filled tape is applied overlapped.
- Jacket is Chlorinated Polyethylene (CPE).
Conforms to ICEA S-66-524 (NEMA WC8).
Notes- Shipping tolerance +/- 10%
-
Type MP-GC 3-Conductor - EPR/CPE or XLP/CPE 8kV 100% Insulation Level (Grounded) 90掳C
Applications
This cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for non-flexing service.
Construction- Conductor is stranded annealed copper enveloped in a strand shield.
- Insulation is Ethylene Propylene Rubber (EPR) or Cross Linked Polyethylene (XLPE).
- Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round.
- A single faced rubber filled tape is applied overlapped.
- Jacket is Chlorinated Polyethylene (CPE).
Conforms to ICEA S-66-524 (NEMA WC8).
Notes- Shipping tolerance +/- 10%
-
Type MP-GC 3-Conductor - EPR/PVC or XLP/PVC 15kV 100% Insulation Level (Grounded) 90掳C
Applications
This cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for non-flexing service.
Construction- Conductor is stranded annealed copper enveloped in a strand shield.
- Insulation is Ethylene Propylene Rubber (EPR) or Cross Linked Polyethylene (XLPE).
- Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round.
- A single faced rubber filled tape is applied overlapped.
- Jacket is Polyvinylchloride (PVC).
- Jacket Options - Chlorinated Polyethylene (CPE) or Hypalon (CPSE).
Conforms to ICEA S-66-524 (NEMA WC8).