Type MP-GC 3-Conductor - EPR/CPE or XLP/CPE 8kV 100% Insulation Level (Grounded) 90°C
Type MP-GC (Mine Power Feeder)
Applications
This cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for non-flexing service.
Construction
Conforms to ICEA S-66-524 (NEMA WC8).
Notes
This cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for non-flexing service.
Construction
- Conductor is stranded annealed copper enveloped in a strand shield.
- Insulation is Ethylene Propylene Rubber (EPR) or Cross Linked Polyethylene (XLPE).
- Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round.
- A single faced rubber filled tape is applied overlapped.
- Jacket is Chlorinated Polyethylene (CPE).
Conforms to ICEA S-66-524 (NEMA WC8).
Notes
- Shipping tolerance +/- 10%
Item # |
Power
|
Power
|
Power
|
Ground Wire
|
Ground Wire
|
Jacket
|
Overall
|
Net Weight
|
---|---|---|---|---|---|---|---|---|
MP8-01-4 MP8-01-4/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size 7mÊÓƵ N/A 4 |
Power Conductors # of Strands N/A 7 |
Power Conductors Insulation Thickness N/A 0.115 Inches |
Ground Wire Size 7mÊÓƵ N/A 8 |
Ground Wire # of Strands N/A 7 |
Jacket Thickness (Inches) N/A 0.11 |
Overall Diameter (inches) N/A 1.43 |
Net Weight Per MFT N/A 1440 Lbs |
MP8-02-2 MP8-02-2/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size 7mÊÓƵ N/A 2 |
Power Conductors # of Strands N/A 7 |
Power Conductors Insulation Thickness N/A 0.115 Inches |
Ground Wire Size 7mÊÓƵ N/A 6 |
Ground Wire # of Strands N/A 7 |
Jacket Thickness (Inches) N/A 0.11 |
Overall Diameter (inches) N/A 1.55 |
Net Weight Per MFT N/A 1760 Lbs |
MP8-03-1 MP8-03-1/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size 7mÊÓƵ N/A 1 |
Power Conductors # of Strands N/A 19 |
Power Conductors Insulation Thickness N/A 0.115 Inches |
Ground Wire Size 7mÊÓƵ N/A 5 |
Ground Wire # of Strands N/A 7 |
Jacket Thickness (Inches) N/A 0.11 |
Overall Diameter (inches) N/A 1.65 |
Net Weight Per MFT N/A 2070 Lbs |
MP8-04-1/0 MP8-04-1/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size 7mÊÓƵ N/A 1/0 |
Power Conductors # of Strands N/A 19 |
Power Conductors Insulation Thickness N/A 0.115 Inches |
Ground Wire Size 7mÊÓƵ N/A 4 |
Ground Wire # of Strands N/A 7 |
Jacket Thickness (Inches) N/A 0.11 |
Overall Diameter (inches) N/A 1.75 |
Net Weight Per MFT N/A 2440 Lbs |
MP8-05-2/0 MP8-05-2/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size 7mÊÓƵ N/A 2/0 |
Power Conductors # of Strands N/A 19 |
Power Conductors Insulation Thickness N/A 0.115 Inches |
Ground Wire Size 7mÊÓƵ N/A 3 |
Ground Wire # of Strands N/A 7 |
Jacket Thickness (Inches) N/A 0.14 |
Overall Diameter (inches) N/A 1.88 |
Net Weight Per MFT N/A 2940 Lbs |
MP8-06-4/0 MP8-06-4/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size 7mÊÓƵ N/A 4/0 |
Power Conductors # of Strands N/A 19 |
Power Conductors Insulation Thickness N/A 0.115 Inches |
Ground Wire Size 7mÊÓƵ N/A 1/0 |
Ground Wire # of Strands N/A 19 |
Jacket Thickness (Inches) N/A 0.14 |
Overall Diameter (inches) N/A 2.12 |
Net Weight Per MFT N/A 4130 Lbs |
MP8-07-250 MP8-07-250/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size 7mÊÓƵ N/A 250 |
Power Conductors # of Strands N/A 37 |
Power Conductors Insulation Thickness N/A 0.115 Inches |
Ground Wire Size 7mÊÓƵ N/A 2/0 |
Ground Wire # of Strands N/A 19 |
Jacket Thickness (Inches) N/A 0.14 |
Overall Diameter (inches) N/A 2.25 |
Net Weight Per MFT N/A 4760 Lbs |
MP8-08-350 MP8-08-350/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size 7mÊÓƵ N/A 350 |
Power Conductors # of Strands N/A 37 |
Power Conductors Insulation Thickness N/A 0.115 Inches |
Ground Wire Size 7mÊÓƵ N/A 3/0 |
Ground Wire # of Strands N/A 19 |
Jacket Thickness (Inches) N/A 0.14 |
Overall Diameter (inches) N/A 2.46 |
Net Weight Per MFT N/A 6090 Lbs |
MP8-09-500 MP8-09-500/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size 7mÊÓƵ N/A 500 |
Power Conductors # of Strands N/A 37 |
Power Conductors Insulation Thickness N/A 0.115 Inches |
Ground Wire Size 7mÊÓƵ N/A 4/0 |
Ground Wire # of Strands N/A 19 |
Jacket Thickness (Inches) N/A 0.14 |
Overall Diameter (inches) N/A 2.75 |
Net Weight Per MFT N/A 8360 Lbs |