TOWERGUARD® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV
TOWERGUARD® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV
Applications
Conductor: 8 7mÊÓƵ thru 1000 kcmil compacted aluminum ACM (AA-8000 Series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE) - Black
Print: TOWERGUARD 2000® XLP 7mÊÓƵ/KCMIL TYPE RHH/RHW-2 SR (UL) 2000V (MM/YYYY) SEQUENTIAL FOOTAGE MARK
Compliances
Colors optional, to order.
All produced or cut-to-order material will be shipped on non-returnable wooden reels unless specifically requested
- For use from the lower control box at the base of the wind power tower and out to the step-up transformer through conduit
- For use in free air, raceways or direct burial in accordance with NEC.
- Industrial environments where superior insulation toughness and chemical resistance is required
- Maximum operating temperature not to exceed 90 ºC in wet or dry locations
Conductor: 8 7mÊÓƵ thru 1000 kcmil compacted aluminum ACM (AA-8000 Series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE) - Black
Print: TOWERGUARD 2000® XLP 7mÊÓƵ/KCMIL TYPE RHH/RHW-2 SR (UL) 2000V (MM/YYYY) SEQUENTIAL FOOTAGE MARK
Compliances
- National Electric Code (NEC)
- UL 44 Stranded for rubber-insulated wires and cables
- ICEA S-95-685/NEMA WC70
- UL listed as Type RHH/RHW-2
- OSHA acceptable
- Rated at 90 ºC wet or dry
- UV resistant - black is marked SR
- Excellent electrical, thermal and physical properties
- Excellent resistance to moisture
- Excellent resistance to crush, compression cuts and heat deformation
Colors optional, to order.
All produced or cut-to-order material will be shipped on non-returnable wooden reels unless specifically requested
Items |
/Asset/TOWERGUARD-XLP.jpg TGXL-08 TOWERGUARD® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV |
/Asset/TOWERGUARD-XLP.jpg TGXL-06 TOWERGUARD® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV |
/Asset/TOWERGUARD-XLP.jpg TGXL-04 TOWERGUARD® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV |
/Asset/TOWERGUARD-XLP.jpg TGXL-02 TOWERGUARD® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV |
/Asset/TOWERGUARD-XLP.jpg TGXL-01 TOWERGUARD® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV |
|||||
Conductor Size 7mÊÓƵ kcmil |
N/A 8 | N/A 6 | N/A 4 | N/A 2 | N/A 1 | |||||
No. of Wires |
N/A 7 | N/A 7 | N/A 7 | N/A 7 | N/A 18 | |||||
Conductor Diameter (in) |
N/A 0.134 | N/A 0.169 | N/A 0.213 | N/A 0.268 | N/A 0.299 | |||||
Insulation Thickness (mil) |
N/A 70 | N/A 70 | N/A 70 | N/A 70 | N/A 90 | |||||
Cable Diameter (in) |
N/A 0.285 | N/A 0.320 | N/A 0.360 | N/A 0.420 | N/A 0.495 | |||||
Aluminum Weight MFT (lb) |
N/A 16 | N/A 25 | N/A 39 | N/A 62 | N/A 79 | |||||
Net Weight MFT (lb) |
N/A 38 | N/A 51 | N/A 72 | N/A 100 | N/A 134 | |||||
Ampacity 90 ºC |
N/A 45 | N/A 60 | N/A 75 | N/A 100 | N/A 115 | |||||
|