Type G Round - 4-Conductor 90°C 600V/2000V
Type G, G-GC
Applications
For use in heavy duty services as power supply cable, mobile and portable electrical. For3 and 4conductor cables use on three phase AC systems where grounding is required.
Construction
Standards
ICEA S-75-381 and MSHA approved.
Notes
For use in heavy duty services as power supply cable, mobile and portable electrical. For3 and 4conductor cables use on three phase AC systems where grounding is required.
Construction
- Conductor is 8 - 500 MCM fully annealed stranded bare copper.
- Insulation is premium grade color coded 90 ºC EPR.
- Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals.
- Rope lay stranding for maximum flex life with excellent impact resistance and cable core bound for superior flexibility and toughness.
- Suitable for continuous submersion in water.
- Jacket is 90 ºC Black CPE with temperature range of -40 ºC to +90 ºC .
- Jacket is Indent printed for easy identification (successive footage printing available).
- Jacket marking is (SIZE) TYPE G 600/200V 90ºC DRY AND WATER RESISTANT ºC SUN RES PK(#) MSHA.
- Lengths cut to order.
Standards
ICEA S-75-381 and MSHA approved.
Notes
- These ampacities are based on a conductor temperature of 90ºC and an ambient air temperature of 40 ºC per ICEA PUB-S-75-381 NEMA WC0-8. For ampacities per National Electrical Code requirements, refer to the latest NEC edition.
- Shipping tolerance +/- 10%
- Heavy duty neoprene jacket optional.
- Successive footage printing available.
Item # |
Number
|
Size
|
Conductor
|
Nominal
|
Nominal
|
Nominal
|
Nominal
|
Current
|
Net Weight
|
Grounding
|
---|---|---|---|---|---|---|---|---|---|---|
4-01-G8 4-01-G8/ImgCustom/1006/placeholder_notavailable.gif |
Number of Conductors N/A 4 |
Size (7mÊÓƵ or kcmil) N/A 8 |
Conductor Stranding N/A 133 |
Nominal Thickness of Insulation (Inches) N/A 0.060 |
Nominal Thickness of Insulation (mm) N/A 1.52 |
Nominal O.D. (Inches) N/A 0.970 |
Nominal O.D. (mm) N/A 24.64 |
Current Amps N/A 54 |
Net Weight Per MFT N/A 635 Lbs |
Grounding Conductor Size 7mÊÓƵ N/A 4 # 12 |
4-02-G6 4-02-G6/ImgCustom/1006/placeholder_notavailable.gif |
Number of Conductors N/A 4 |
Size (7mÊÓƵ or kcmil) N/A 6 |
Conductor Stranding N/A 259 |
Nominal Thickness of Insulation (Inches) N/A 0.060 |
Nominal Thickness of Insulation (mm) N/A 1.52 |
Nominal O.D. (Inches) N/A 1.110 |
Nominal O.D. (mm) N/A 28.19 |
Current Amps N/A 72 |
Net Weight Per MFT N/A 900 Lbs |
Grounding Conductor Size 7mÊÓƵ N/A 4 # 12 |
4-03-G4 4-03-G4/ImgCustom/1006/placeholder_notavailable.gif |
Number of Conductors N/A 4 |
Size (7mÊÓƵ or kcmil) N/A 4 |
Conductor Stranding N/A 259 |
Nominal Thickness of Insulation (Inches) N/A 0.060 |
Nominal Thickness of Insulation (mm) N/A 1.52 |
Nominal O.D. (Inches) N/A 1.245 |
Nominal O.D. (mm) N/A 31.62 |
Current Amps N/A 93 |
Net Weight Per MFT N/A 1280 Lbs |
Grounding Conductor Size 7mÊÓƵ N/A 4 # 10 |
4-04-G2 4-04-G2/ImgCustom/1006/placeholder_notavailable.gif |
Number of Conductors N/A 4 |
Size (7mÊÓƵ or kcmil) N/A 2 |
Conductor Stranding N/A 259 |
Nominal Thickness of Insulation (Inches) N/A 0.060 |
Nominal Thickness of Insulation (mm) N/A 1.52 |
Nominal O.D. (Inches) N/A 1.470 |
Nominal O.D. (mm) N/A 37.34 |
Current Amps N/A 122 |
Net Weight Per MFT N/A 2000 Lbs |
Grounding Conductor Size 7mÊÓƵ N/A 4 # 9 |
4-05-G1 4-05-G1/ImgCustom/1006/placeholder_notavailable.gif |
Number of Conductors N/A 4 |
Size (7mÊÓƵ or kcmil) N/A 1 |
Conductor Stranding N/A 259 |
Nominal Thickness of Insulation (Inches) N/A 0.08 |
Nominal Thickness of Insulation (mm) N/A 2.03 |
Nominal O.D. (Inches) N/A 1.680 |
Nominal O.D. (mm) N/A 42.67 |
Current Amps N/A 143 |
Net Weight Per MFT N/A 2660 Lbs |
Grounding Conductor Size 7mÊÓƵ N/A 4 # 8 |
4-06-G10 4-06-G10/ImgCustom/1006/placeholder_notavailable.gif |
Number of Conductors N/A 4 |
Size (7mÊÓƵ or kcmil) N/A 1/0 |
Conductor Stranding N/A 259 |
Nominal Thickness of Insulation (Inches) N/A 0.08 |
Nominal Thickness of Insulation (mm) N/A 2.03 |
Nominal O.D. (Inches) N/A 1.790 |
Nominal O.D. (mm) N/A 45.47 |
Current Amps N/A 165 |
Net Weight Per MFT N/A 3140 Lbs |
Grounding Conductor Size 7mÊÓƵ N/A 4 # 7 |
4-07-G20 4-07-G20/ImgCustom/1006/placeholder_notavailable.gif |
Number of Conductors N/A 4 |
Size (7mÊÓƵ or kcmil) N/A 2/0 |
Conductor Stranding N/A 259 |
Nominal Thickness of Insulation (Inches) N/A 0.08 |
Nominal Thickness of Insulation (mm) N/A 2.03 |
Nominal O.D. (Inches) N/A 1.930 |
Nominal O.D. (mm) N/A 49.02 |
Current Amps N/A 192 |
Net Weight Per MFT N/A 3780 Lbs |
Grounding Conductor Size 7mÊÓƵ N/A 4 # 6 |
4-08-G30 4-08-G30/ImgCustom/1006/placeholder_notavailable.gif |
Number of Conductors N/A 4 |
Size (7mÊÓƵ or kcmil) N/A 3/0 |
Conductor Stranding N/A 259 |
Nominal Thickness of Insulation (Inches) N/A 0.08 |
Nominal Thickness of Insulation (mm) N/A 2.03 |
Nominal O.D. (Inches) N/A 2.070 |
Nominal O.D. (mm) N/A 52.58 |
Current Amps N/A 221 |
Net Weight Per MFT N/A 4500 Lbs |
Grounding Conductor Size 7mÊÓƵ N/A 4 # 5 |
4-09-G40 4-09-G40/ImgCustom/1006/placeholder_notavailable.gif |
Number of Conductors N/A 4 |
Size (7mÊÓƵ or kcmil) N/A 4/0 |
Conductor Stranding N/A 259 |
Nominal Thickness of Insulation (Inches) N/A 0.08 |
Nominal Thickness of Insulation (mm) N/A 2.03 |
Nominal O.D. (Inches) N/A 2.260 |
Nominal O.D. (mm) N/A 57.40 |
Current Amps N/A 255 |
Net Weight Per MFT N/A 5520 Lbs |
Grounding Conductor Size 7mÊÓƵ N/A 4 # 4 |