12 7mÊÓƵ THWN or THHN PVC Jacket, 600V, 2/C - 37/C
TFN, THWN, or THHN - PVC Jacket, 600V
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600 volts, 90 Deg. C. in dry locations, 75 Deg. C. in wet locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Individual conductors of stranded uncoated copper Type TFN (167mÊÓƵ). Type THWN or THHN (14-10 7mÊÓƵ), color coded, two conductors flat, three or more conductors twisted, PVC jacket overall, surface printed.
Standards
As flame-retardant multi-conductor control, signal or power cables rated 600 volts, 90 Deg. C. in dry locations, 75 Deg. C. in wet locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Individual conductors of stranded uncoated copper Type TFN (167mÊÓƵ). Type THWN or THHN (14-10 7mÊÓƵ), color coded, two conductors flat, three or more conductors twisted, PVC jacket overall, surface printed.
Standards
- Listed by UL as Type TC Tray Cable per Article 336 of the NEC.
- Individual conductors UL listed as Type THWN or THHN (14-10 7mÊÓƵ) or Type TFN (16 7mÊÓƵ).
- Overall jacket UL listed as Sunlight Resistant.
- Cables UL listed for Direct Burial.
- Cables with grounding conductor UL listed for Open Wiring.
- Cables pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hour test.
- Cables designated (w/g) contain an additional bare copper grounding conductor, same size as circuit conductors, and are UL listed for Open Wiring.
- Standard color coding is ICEA Method E2 or K2 for NEC applications. This color coding method omits white and green from the color sequence.
- ICEA Method 4 color coding is also provided. This consists of printed numbers and words, 1-ONE, 2-TWO, etc.
- Size 16 7mÊÓƵ is rated 90ºC dry only.
Item # |
Number
|
Size
|
Number
|
Overall
|
Nominal
|
Weight
|
---|---|---|---|---|---|---|
12-TC1-2 12-TC1-2/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 2 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 45 |
Nominal Diameter (in) N/A .23 x .37 |
Weight (lb/1000 ft) N/A 75 Lbs |
12-TC1-3 12-TC1-3/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 3 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 45 |
Nominal Diameter (in) N/A 0.36 |
Weight (lb/1000 ft) N/A 105 Lbs |
12-TC1-3 w/g 12-TC1-3 w/g/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 3 w/g |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 45 |
Nominal Diameter (in) N/A 0.40 |
Weight (lb/1000 ft) N/A 130 Lbs |
12-TC1-4 12-TC1-4/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 4 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 45 |
Nominal Diameter (in) N/A 0.40 |
Weight (lb/1000 ft) N/A 135 Lbs |
12-TC1-5 12-TC1-5/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 5 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 45 |
Nominal Diameter (in) N/A 0.45 |
Weight (lb/1000 ft) N/A 165 Lbs |
12-TC1-6 12-TC1-6/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 6 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 45 |
Nominal Diameter (in) N/A 0.50 |
Weight (lb/1000 ft) N/A 195 Lbs |
12-TC1-7 12-TC1-7/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 7 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 45 |
Nominal Diameter (in) N/A 0.50 |
Weight (lb/1000 ft) N/A 215 Lbs |
12-TC1-8 12-TC1-8/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 8 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.58 |
Weight (lb/1000 ft) N/A 260 Lbs |
12-TC1-9 12-TC1-9/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 9 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.62 |
Weight (lb/1000 ft) N/A 300 Lbs |
12-TC1-10 12-TC1-10/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 10 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.66 |
Weight (lb/1000 ft) N/A 325 Lbs |
12-TC1-11 12-TC1-11/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 11 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.66 |
Weight (lb/1000 ft) N/A 350 Lbs |
12-TC1-12 12-TC1-12/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 12 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.68 |
Weight (lb/1000 ft) N/A 375 Lbs |
12-TC1-13 12-TC1-13/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 13 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.70 |
Weight (lb/1000 ft) N/A 400 Lbs |
12-TC1-14 12-TC1-14/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 14 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.73 |
Weight (lb/1000 ft) N/A 425 Lbs |
12-TC1-15 12-TC1-15/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 15 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.76 |
Weight (lb/1000 ft) N/A 455 Lbs |
12-TC1-16 12-TC1-16/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 16 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.76 |
Weight (lb/1000 ft) N/A 485 Lbs |
12-TC1-17 12-TC1-17/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 17 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.79 |
Weight (lb/1000 ft) N/A 515 Lbs |
12-TC1-18 12-TC1-18/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 18 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.79 |
Weight (lb/1000 ft) N/A 545 Lbs |
12-TC1-19 12-TC1-19/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 19 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 60 |
Nominal Diameter (in) N/A 0.79 |
Weight (lb/1000 ft) N/A 656 Lbs |
12-TC1-20 12-TC1-20/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 20 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 80 |
Nominal Diameter (in) N/A 0.89 |
Weight (lb/1000 ft) N/A 590 Lbs |
12-TC1-23 12-TC1-23/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 23 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 80 |
Nominal Diameter (in) N/A 0.93 |
Weight (lb/1000 ft) N/A 690 Lbs |
12-TC1-25 12-TC1-25/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 25 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 80 |
Nominal Diameter (in) N/A 0.96 |
Weight (lb/1000 ft) N/A 770 Lbs |
12-TC1-27 12-TC1-27/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 27 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 80 |
Nominal Diameter (in) N/A 1.00 |
Weight (lb/1000 ft) N/A 840 Lbs |
12-TC1-29 12-TC1-29/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 29 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 80 |
Nominal Diameter (in) N/A 1.01 |
Weight (lb/1000 ft) N/A 910 Lbs |
12-TC1-31 12-TC1-31/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 31 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 80 |
Nominal Diameter (in) N/A 1.06 |
Weight (lb/1000 ft) N/A 950 Lbs |
12-TC1-32 12-TC1-32/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 32 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 80 |
Nominal Diameter (in) N/A 1.08 |
Weight (lb/1000 ft) N/A 1000 Lbs |
12-TC1-37 12-TC1-37/Asset/VNTC-PVC-Jacket-600V.png |
Number of Conductors N/A 37 |
Size (7mÊÓƵ or kcmil) N/A 12 |
Number of Strands N/A 7 |
Overall PVC Jacket (mils) N/A 80 |
Nominal Diameter (in) N/A 1.10 |
Weight (lb/1000 ft) N/A 1090 Lbs |