Welding Cable - 600V ICEA Approved - 105°C -40°C
Welding Cable
Applications
Designed for Connections from electrode holders and clamps to arc welders, bus welding box or transformer
Recommended for use in shipyards, mines, and other areas where cable is subject to extreme physical abuse. Flame retardant, oil resistant, resilient, resists compression cuts and abrasion, durable handling.
This cable is not suitable for in line voltage use. Improper use could be hazardous to personnel and could damage equipment.
Construction
Meets ASTM B-3 ASTM B1732, ICEA S-175-381, IEC 254-1.
Available on Request
(PDF, 112KB)"
Designed for Connections from electrode holders and clamps to arc welders, bus welding box or transformer
Recommended for use in shipyards, mines, and other areas where cable is subject to extreme physical abuse. Flame retardant, oil resistant, resilient, resists compression cuts and abrasion, durable handling.
This cable is not suitable for in line voltage use. Improper use could be hazardous to personnel and could damage equipment.
Construction
- Conductor is annealed rope stranded bare copper conductor per ICEA S-75-381.
- Insulation is Ethylene Propylene Rubber (EPR) type EP, Class 45, 105 C. Table 50.55 of UL.1581.
- Separator between conductor and jacket is crepe paper.
- Voltage is 600 Volts spark tested.
Meets ASTM B-3 ASTM B1732, ICEA S-175-381, IEC 254-1.
Available on Request
- Class M stranding
- Colors
- Hypalon or Neoprene Insulation
- UL or CSA Listed
- Custom Cut Lengths
- Nominal resistance of conductor acc to ICEA S-75-381 Class K
(PDF, 112KB)"
Item # |
Size
|
Nominal
|
Nominal
|
Nominal
|
Nominal
|
Copper
|
Weight
|
Amps |
---|---|---|---|---|---|---|---|---|
W01-6 W01-6/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 6 |
Nominal Stranding Class K N/A 285/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A 0.4190 |
Nominal Thickness of Insulation (Inches) N/A 0.059 |
Nominal O.D. (Inches) N/A 0.319 |
Copper Content Lbs./MFT N/A 83 |
Weight (lb/1000 ft) N/A 120 Lbs |
Amps N/A 75 |
W02-4 W02-4/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 4 |
Nominal Stranding Class K N/A 412/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A 0.2630 |
Nominal Thickness of Insulation (Inches) N/A 0.059 |
Nominal O.D. (Inches) N/A 0.366 |
Copper Content Lbs./MFT N/A 133 |
Weight (lb/1000 ft) N/A 180 Lbs |
Amps N/A 100 |
W03-2 W03-2/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 2 |
Nominal Stranding Class K N/A 647/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A 0.1670 |
Nominal Thickness of Insulation (Inches) N/A 0.071 |
Nominal O.D. (Inches) N/A 0.429 |
Copper Content Lbs./MFT N/A 213 |
Weight (lb/1000 ft) N/A 260 Lbs |
Amps N/A 140 |
W04-1 W04-1/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 1 |
Nominal Stranding Class K N/A 817/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A 0.1330 |
Nominal Thickness of Insulation (Inches) N/A 0.071 |
Nominal O.D. (Inches) N/A 0.508 |
Copper Content Lbs./MFT N/A 266 |
Weight (lb/1000 ft) N/A 320 Lbs |
Amps N/A 160 |
W05-1/0 W05-1/0/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 1/0 |
Nominal Stranding Class K N/A 1021/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A 0.1050 |
Nominal Thickness of Insulation (Inches) N/A 0.079 |
Nominal O.D. (Inches) N/A 0.555 |
Copper Content Lbs./MFT N/A 342 |
Weight (lb/1000 ft) N/A 400 Lbs |
Amps N/A 190 |
W06-2/0 W06-2/0/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 2/0 |
Nominal Stranding Class K N/A 1289/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A 0.0842 |
Nominal Thickness of Insulation (Inches) N/A 0.079 |
Nominal O.D. (Inches) N/A 0.598 |
Copper Content Lbs./MFT N/A 433 |
Weight (lb/1000 ft) N/A 500 Lbs |
Amps N/A 223 |
W07-3/0 W07-3/0/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 3/0 |
Nominal Stranding Class K N/A 1650/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A 0.0668 |
Nominal Thickness of Insulation (Inches) N/A 0.079 |
Nominal O.D. (Inches) N/A 0.673 |
Copper Content Lbs./MFT N/A 538 |
Weight (lb/1000 ft) N/A 610 Lbs |
Amps N/A 265 |
W08-4/0 W08-4/0/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 4/0 |
Nominal Stranding Class K N/A 2065/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A 0.0530 |
Nominal Thickness of Insulation (Inches) N/A 0.079 |
Nominal O.D. (Inches) N/A 0.716 |
Copper Content Lbs./MFT N/A 687 |
Weight (lb/1000 ft) N/A 760 Lbs |
Amps N/A 310 |
W09-250 W09-250/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 250MCM |
Nominal Stranding Class K N/A 2479/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A |
Nominal Thickness of Insulation (Inches) N/A 0.125 |
Nominal O.D. (Inches) N/A 0.866 |
Copper Content Lbs./MFT N/A 804 |
Weight (lb/1000 ft) N/A 855 Lbs |
Amps N/A 445 |
W10-350 W10-350/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 350MCM |
Nominal Stranding Class K N/A 3416/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A |
Nominal Thickness of Insulation (Inches) N/A 0.125 |
Nominal O.D. (Inches) N/A 0.953 |
Copper Content Lbs./MFT N/A 1120 |
Weight (lb/1000 ft) N/A 1255 Lbs |
Amps N/A 552 |
W11-500 W11-500/Asset/welding_cable.jpg |
Size (7mÊÓƵ or kcmil) N/A 500MCM |
Nominal Stranding Class K N/A 4921/30 |
Nominal Resistance of Conductor at 25 ºC per MFT N/A |
Nominal Thickness of Insulation (Inches) N/A 0.125 |
Nominal O.D. (Inches) N/A 1.130 |
Copper Content Lbs./MFT N/A 1638 |
Weight (lb/1000 ft) N/A 1800 Lbs |
Amps N/A 695 |