Quadruplex Conductor 600V Secondary Type URD Cable (8000) RHH/RHW-2 USE-2 - Aluminum Conductor
Quadruplex Conductor Type URD Cable - Aluminum Conductor
Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
Construction
Concentric stranded or compressed (8176-H24) aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Three phase and one neutral conductor cabled together (LH lay) or parallel if so specified. Black neutrals may be specified is desired.
Standards
Secondary URD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Directly buried or installed in ducts for 600 volt secondary distribution.
Construction
Concentric stranded or compressed (8176-H24) aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Three phase and one neutral conductor cabled together (LH lay) or parallel if so specified. Black neutrals may be specified is desired.
Standards
Secondary URD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
- B-800 8000 Series Aluminum Alloy Wire for Electrical Purposes
- B-801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation.
- B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
- Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
- UL Standard 44 for Type RHH or RHW-2
- UL standard 854 for Type USE-2.
- Cable in Duct (CIC)
- Abrasion Resistant
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Item # |
Phase
|
Phase
|
Phase
|
Neutral Size 7mÊÓƵ |
Neutral Stranding |
Neutral Insulation Thickness |
Single
|
Outside
|
Weight
|
Ampacity
|
Ampacity
|
---|---|---|---|---|---|---|---|---|---|---|---|
Tulsa Tulsa/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 4 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size 7mÊÓƵ N/A 4 | Neutral Stranding N/A 7 | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .345 Inches |
Outside Diameter N/A .833 Inches |
Weight (lb/1000 ft) N/A 258 Lbs |
Ampacity Direct Burial N/A 119 Amps |
Ampacity In Duct N/A 85 Amps |
Dyke Dyke/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 2 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size 7mÊÓƵ N/A 4 | Neutral Stranding N/A 7 | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .403 Inches |
Outside Diameter N/A .938 Inches |
Weight (lb/1000 ft) N/A 346 Lbs |
Ampacity Direct Burial N/A 153 Amps |
Ampacity In Duct N/A 115 Amps |
Wittenberg Wittenberg/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 2 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size 7mÊÓƵ N/A 2 | Neutral Stranding N/A 7 | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .403 Inches |
Outside Diameter N/A .973 Inches |
Weight (lb/1000 ft) N/A 375 Lbs |
Ampacity Direct Burial N/A 153 Amps |
Ampacity In Duct N/A 115 Amps |
Notre Dame Notre Dame/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 1/0 |
Phase Conductor Stranding N/A 19 |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 2 | Neutral Stranding N/A 7 | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .522 Inches |
Outside Diameter N/A 1.188 Inches |
Weight (lb/1000 ft) N/A 541 Lbs |
Ampacity Direct Burial N/A 198 Amps |
Ampacity In Duct N/A 150 Amps |
Purdue Purdue/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 1/0 |
Phase Conductor Stranding N/A 19 |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 1/0 | Neutral Stranding N/A 19 | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .522 Inches |
Outside Diameter N/A 1.260 Inches |
Weight (lb/1000 ft) N/A 596 Lbs |
Ampacity Direct Burial N/A 198 Amps |
Ampacity In Duct N/A 150 Amps |
Syracuse Syracuse/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 2/0 |
Phase Conductor Stranding N/A 19 |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 1 | Neutral Stranding N/A 19 | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .566 Inches |
Outside Diameter N/A 1.316 Inches |
Weight (lb/1000 ft) N/A 664 Lbs |
Ampacity Direct Burial N/A 225 Amps |
Ampacity In Duct N/A 170 Amps |
Lafayette Lafayette/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 2/0 |
Phase Conductor Stranding N/A 19 |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 2/0 | Neutral Stranding N/A 19 | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .566 Inches |
Outside Diameter N/A 1.367 Inches |
Weight (lb/1000 ft) N/A 720 Lbs |
Ampacity Direct Burial N/A 225 Amps |
Ampacity In Duct N/A 170 Amps |
Swarthmore Swarthmore/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 3/0 |
Phase Conductor Stranding N/A 19 |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 1/0 | Neutral Stranding N/A 1/0 | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .616 Inches |
Outside Diameter N/A 1.430 Inches |
Weight (lb/1000 ft) N/A 805 Lbs |
Ampacity Direct Burial N/A 250 Amps |
Ampacity In Duct N/A 195 Amps |
Davidson Davidson/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 3/0 |
Phase Conductor Stranding N/A 19 |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 3/0 | Neutral Stranding N/A 19 | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .616 Inches |
Outside Diameter N/A 1.487 Inches |
Weight (lb/1000 ft) N/A 874 Lbs |
Ampacity Direct Burial N/A 250 Amps |
Ampacity In Duct N/A 195 Amps |
Wake Forest Wake Forest/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 4/0 |
Phase Conductor Stranding N/A 19 |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 2/0 | Neutral Stranding N/A 19 | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .672 Inches |
Outside Diameter N/A 1.560 Inches |
Weight (lb/1000 ft) N/A 979 Lbs |
Ampacity Direct Burial N/A 290 Amps |
Ampacity In Duct N/A 225 Amps |
Earlham Earlham/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 4/0 |
Phase Conductor Stranding N/A 19 |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 4/0 | Neutral Stranding N/A 19 | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .672 Inches |
Outside Diameter N/A 1.623 Inches |
Weight (lb/1000 ft) N/A 1066 Lbs |
Ampacity Direct Burial N/A 290 Amps |
Ampacity In Duct N/A 225 Amps |
Slippery Rock Slippery Rock/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 350 |
Phase Conductor Stranding N/A 37 |
Phase Conductor Insulation Thickness N/A 95 mls |
Neutral Size 7mÊÓƵ N/A 4/0 | Neutral Stranding N/A 19 | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .851 Inches |
Outside Diameter N/A 1.945 Inches |
Weight (lb/1000 ft) N/A 1544.0 Lbs |
Ampacity Direct Burial N/A 385 Amps |
Ampacity In Duct N/A 305 Amps |
Wofford Wofford/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 500 |
Phase Conductor Stranding N/A 37 |
Phase Conductor Insulation Thickness N/A 95 mls |
Neutral Size 7mÊÓƵ N/A 350 | Neutral Stranding N/A 37 | Neutral Insulation Thickness N/A 95 mls |
Single Phase Conductor N/A .851 Inches |
Outside Diameter N/A 2.348 Inches |
Weight (lb/1000 ft) N/A 2174 Lbs |
Ampacity Direct Burial N/A 467 Amps |
Ampacity In Duct N/A 420 Amps |
Windham Windham/Asset/QUADRUPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 750 |
Phase Conductor Stranding N/A 61 |
Phase Conductor Insulation Thickness N/A 110 mls |
Neutral Size 7mÊÓƵ N/A 500 | Neutral Stranding N/A 37 | Neutral Insulation Thickness N/A 95 mls |
Single Phase Conductor N/A .979 Inches |
Outside Diameter N/A 2.850 Inches |
Weight (lb/1000 ft) N/A 2542 Lbs |
Ampacity Direct Burial N/A 615 Amps |
Ampacity In Duct N/A 492 Amps |