Quadruplex Service Drop Aluminum Conductors AAAC 6201 Alloy Neutral-Messenger
Quadruplex Service Drop Aluminum Conductor
Applications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors or 90 ºC for crosslinked polyethylene (XLP) insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201 alloy. One conductor is manufactured with an extruded ridge for phase identification.
Standards
Designated sizes are : ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for 6201.Conductor temperature of 90 ºC for XLR 75 ºC for Poly; ambient temperatures of 40 ºC emissivity 0.9; 2ft./sec/wind in sun. To determine current ampacity by conductor size, please consult The National Electric Code, latest edition.
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors or 90 ºC for crosslinked polyethylene (XLP) insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201 alloy. One conductor is manufactured with an extruded ridge for phase identification.
Standards
- B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
- B-231 Aluminum conductors, Concentric-Lay-Stranded.
- B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
- B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
- B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
- Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
Designated sizes are : ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for 6201.Conductor temperature of 90 ºC for XLR 75 ºC for Poly; ambient temperatures of 40 ºC emissivity 0.9; 2ft./sec/wind in sun. To determine current ampacity by conductor size, please consult The National Electric Code, latest edition.
Item # |
Phase
|
Phase
|
Phase
|
Bare
|
Bare
|
Bare
|
Weight
|
Weight
|
Ampacity
|
Ampacity
|
---|---|---|---|---|---|---|---|---|---|---|
Bay Bay/Asset/QUAD-SERVICE-DROP.jpg |
Phase Conductor Size/7mÊÓƵ N/A 6 |
Phase Conductor Stranding N/A Solid |
Phase Conductor Insulation Thickness N/A 45 mls |
Bare Neutral Messenger Size/7mÊÓƵ N/A 6 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength N/A 1110 Lbs |
Weight Per (lb/1000 ft) XLP N/A 145 Lbs |
Weight (lb/1000 ft) Poly N/A 140.0 Lbs |
Ampacity XLP N/A 75 Amps |
Ampacity Poly N/A 60 Amps |
French Coach French Coach/Asset/QUAD-SERVICE-DROP.jpg |
Phase Conductor Size/7mÊÓƵ N/A 6 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 45 mls |
Bare Neutral Messenger Size/7mÊÓƵ N/A 6 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength N/A 1110 Lbs |
Weight Per (lb/1000 ft) XLP N/A 155 Lbs |
Weight (lb/1000 ft) Poly N/A 144.3 Lbs |
Ampacity XLP N/A 75 Amps |
Ampacity Poly N/A 60 Amps |
German Coach German Coach/Asset/QUAD-SERVICE-DROP.jpg |
Phase Conductor Size/7mÊÓƵ N/A 4 |
Phase Conductor Stranding N/A Solid |
Phase Conductor Insulation Thickness N/A 45 mls |
Bare Neutral Messenger Size/7mÊÓƵ N/A 4 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength N/A 1760 Lbs |
Weight Per (lb/1000 ft) XLP N/A 214 Lbs |
Weight (lb/1000 ft) Poly N/A 208.3 Lbs |
Ampacity XLP N/A 100 Amps |
Ampacity Poly N/A 80 Amps |
Arabian Arabian/Asset/QUAD-SERVICE-DROP.jpg |
Phase Conductor Size/7mÊÓƵ N/A 4 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 45 mls |
Bare Neutral Messenger Size/7mÊÓƵ N/A 4 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength N/A 1760 Lbs |
Weight Per (lb/1000 ft) XLP N/A 229 Lbs |
Weight (lb/1000 ft) Poly N/A 214.4 Lbs |
Ampacity XLP N/A 100 Amps |
Ampacity Poly N/A 80 Amps |
Belgian Belgian/Asset/QUAD-SERVICE-DROP.jpg |
Phase Conductor Size/7mÊÓƵ N/A 2 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 45 mls |
Bare Neutral Messenger Size/7mÊÓƵ N/A 2 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength N/A 2800 Lbs |
Weight Per (lb/1000 ft) XLP N/A 344 Lbs |
Weight (lb/1000 ft) Poly N/A 323.1 Lbs |
Ampacity XLP N/A 135 Amps |
Ampacity Poly N/A 105 Amps |
Shetland Shetland/Asset/QUAD-SERVICE-DROP.jpg |
Phase Conductor Size/7mÊÓƵ N/A 1/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Bare Neutral Messenger Size/7mÊÓƵ N/A 1/0 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength N/A 4460 Lbs |
Weight Per (lb/1000 ft) XLP N/A 546 Lbs |
Weight (lb/1000 ft) Poly N/A 521.1 Lbs |
Ampacity XLP N/A 180 Amps |
Ampacity Poly N/A 140 Amps |
Thoroughbred Thoroughbred/Asset/QUAD-SERVICE-DROP.jpg |
Phase Conductor Size/7mÊÓƵ N/A 2/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Bare Neutral Messenger Size/7mÊÓƵ N/A 2/0 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength N/A 5390 Lbs |
Weight Per (lb/1000 ft) XLP N/A 670 Lbs |
Weight (lb/1000 ft) Poly N/A 641.5 Lbs |
Ampacity XLP N/A 205 Amps |
Ampacity Poly N/A 160 Amps |
Trotter Trotter/Asset/QUAD-SERVICE-DROP.jpg |
Phase Conductor Size/7mÊÓƵ N/A 3/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Bare Neutral Messenger Size/7mÊÓƵ N/A 3/0 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength N/A 6790 Lbs |
Weight Per (lb/1000 ft) XLP N/A 825 Lbs |
Weight (lb/1000 ft) Poly N/A 791.8 Lbs |
Ampacity XLP N/A 235 Amps |
Ampacity Poly N/A 185 Amps |
Walking Walking/Asset/QUAD-SERVICE-DROP.jpg |
Phase Conductor Size/7mÊÓƵ N/A 4/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Bare Neutral Messenger Size/7mÊÓƵ N/A 4/0 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength N/A 8560 Lbs |
Weight Per (lb/1000 ft) XLP N/A 1019 Lbs |
Weight (lb/1000 ft) Poly N/A 979.7 Lbs |
Ampacity XLP N/A 275 Amps |
Ampacity Poly N/A 210 Amps |