Triplex Conductor 600V Secondary Type URD Cable - (8000) RHH/RHW-2 USE-2 - Aluminum Conductor
Triplex Conductor Type URD Cable - Aluminum Conductor
Applications
Used for secondary distribution and underground service at 600 volts or less, either direct burial or in ducts.
Construction
Concentric stranded or compressed 8000 (8176-H24) aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Two phase and one neutral conductor twisted together (LH lay) to produce the triplex cable configuration, or parallel if so specified. Black neutrals may be specified if desired.
Standards
Secondary URD triplex conductor 600V cable meets or exceeds the following ASTM specifications.
90ºC conductor temperature, 20ºC ambient, RHO 50, 100% load factor for three conductor triplex with neutral carrying only unbalanced load. Technical data for cable with solid black neutral is identical to yellow extruded stripe data. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Used for secondary distribution and underground service at 600 volts or less, either direct burial or in ducts.
Construction
Concentric stranded or compressed 8000 (8176-H24) aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Two phase and one neutral conductor twisted together (LH lay) to produce the triplex cable configuration, or parallel if so specified. Black neutrals may be specified if desired.
Standards
Secondary URD triplex conductor 600V cable meets or exceeds the following ASTM specifications.
- B-800 8000 Series Aluminum Alloy Wire for Electrical Purposes
- B-801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation.
- B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
- Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
- UL Standard 44 for Type RHH or RHW-2
- UL standard 854 for Type USE-2.
- Cable in Duct (CIC)
- Abrasion Resistant
90ºC conductor temperature, 20ºC ambient, RHO 50, 100% load factor for three conductor triplex with neutral carrying only unbalanced load. Technical data for cable with solid black neutral is identical to yellow extruded stripe data. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Item # |
Phase
|
Phase
|
Phase
|
Neutral Size 7mÊÓƵ |
Neutral Stranding |
Neutral Insulation Thickness |
Single
|
Outside
|
Weight
|
Ampacity
|
Ampacity
|
---|---|---|---|---|---|---|---|---|---|---|---|
Erskine Erskine/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 6 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size 7mÊÓƵ N/A 6 | Neutral Stranding N/A 7/w | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .299 Inches |
Outside Diameter N/A .646 Inches |
Weight (lb/1000 ft) N/A 143 Lbs |
Ampacity Direct Burial N/A 95 Amps |
Ampacity In Duct N/A 70 Amps |
Vassar Vassar/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 4 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size 7mÊÓƵ N/A 4 | Neutral Stranding N/A 7/w | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .345 Inches |
Outside Diameter N/A .754 Inches |
Weight (lb/1000 ft) N/A 203 Lbs |
Ampacity Direct Burial N/A 125 Amps |
Ampacity In Duct N/A 90 Amps |
Stephens Stephens/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 2 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size 7mÊÓƵ N/A 4 | Neutral Stranding N/A 7/w | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .403 Inches |
Outside Diameter N/A .842 Inches |
Weight (lb/1000 ft) N/A 264 Lbs |
Ampacity Direct Burial N/A 165 Amps |
Ampacity In Duct N/A 120 Amps |
Ramapo Ramapo/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 2 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size 7mÊÓƵ N/A 2 | Neutral Stranding N/A 7/w | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .403 Inches |
Outside Diameter N/A .874 Inches |
Weight (lb/1000 ft) N/A 294 Lbs |
Ampacity Direct Burial N/A 165 Amps |
Ampacity In Duct N/A 120 Amps |
Brenau Brenau/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 1/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 2 | Neutral Stranding N/A 7/w | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .522 Inches |
Outside Diameter N/A 1.064 Inches |
Weight (lb/1000 ft) N/A 408 Lbs |
Ampacity Direct Burial N/A 215 Amps |
Ampacity In Duct N/A 160 Amps |
Bergen Bergen/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 1/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 1/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .522 Inches |
Outside Diameter N/A 1.133 Inches |
Weight (lb/1000 ft) N/A 465 Lbs |
Ampacity Direct Burial N/A 215 Amps |
Ampacity In Duct N/A 160 Amps |
Converse Converse/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 2/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 1 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .566 Inches |
Outside Diameter N/A 1.174 Inches |
Weight (lb/1000 ft) N/A 502 Lbs |
Ampacity Direct Burial N/A 245 Amps |
Ampacity In Duct N/A 160 Amps |
Hunter Hunter/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 2/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 2/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .566 Inches |
Outside Diameter N/A 1.228 Inches |
Weight (lb/1000 ft) N/A 560 Lbs |
Ampacity Direct Burial N/A 245 Amps |
Ampacity In Duct N/A 180 Amps |
Hollins Hollins/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 3/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 1/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .616 Inches |
Outside Diameter N/A 1.276 Inches |
Weight (lb/1000 ft) N/A 606 Lbs |
Ampacity Direct Burial N/A 280 Amps |
Ampacity In Duct N/A 205 Amps |
Rockland Rockland/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 3/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 3/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .616 Inches |
Outside Diameter N/A 1.336 Inches |
Weight (lb/1000 ft) N/A 678 Lbs |
Ampacity Direct Burial N/A 280 Amps |
Ampacity In Duct N/A 205 Amps |
Sweetbriar Sweetbriar/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 4/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 2/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .672 Inches |
Outside Diameter N/A 1.389 Inches |
Weight (lb/1000 ft) N/A 739 Lbs |
Ampacity Direct Burial N/A 315 Amps |
Ampacity In Duct N/A 240 Amps |
Monmouth Monmouth/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 4/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size 7mÊÓƵ N/A 4/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .672 Inches |
Outside Diameter N/A 1.457 Inches |
Weight (lb/1000 ft) N/A 828 Lbs |
Ampacity Direct Burial N/A 315 Amps |
Ampacity In Duct N/A 240 Amps |
Pratt Pratt/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 250 |
Phase Conductor Stranding N/A 37/w |
Phase Conductor Insulation Thickness N/A 95 mls |
Neutral Size 7mÊÓƵ N/A 3/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .748 Inches |
Outside Diameter N/A 1.538 Inches |
Weight (lb/1000 ft) N/A 893 Lbs |
Ampacity Direct Burial N/A 345 Amps |
Ampacity In Duct N/A 265 Amps |
Wesleyan Wesleyan/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 350 |
Phase Conductor Stranding N/A 37/w |
Phase Conductor Insulation Thickness N/A 95 mls |
Neutral Size 7mÊÓƵ N/A 4/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .851 Inches |
Outside Diameter N/A 1.736 Inches |
Weight (lb/1000 ft) N/A 1166 Lbs |
Ampacity Direct Burial N/A 415 Amps |
Ampacity In Duct N/A 320 Amps |
Holyoke Holyoke/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 500 |
Phase Conductor Stranding N/A 37/w |
Phase Conductor Insulation Thickness N/A 95 mls |
Neutral Size 7mÊÓƵ N/A 300 | Neutral Stranding N/A 37/w | Neutral Insulation Thickness N/A 95 mls |
Single Phase Conductor N/A .979 Inches |
Outside Diameter N/A 2.008 Inches |
Weight (lb/1000 ft) N/A 1607 Lbs |
Ampacity Direct Burial N/A 495 Amps |
Ampacity In Duct N/A 395 Amps |
Rider Rider/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 500 |
Phase Conductor Stranding N/A 37/w |
Phase Conductor Insulation Thickness N/A 95 mls |
Neutral Size 7mÊÓƵ N/A 350 | Neutral Stranding N/A 37/w | Neutral Insulation Thickness N/A 95 mls |
Single Phase Conductor N/A .979 Inches |
Outside Diameter N/A 2.035 Inches |
Weight (lb/1000 ft) N/A 1663 Lbs |
Ampacity Direct Burial N/A 495 Amps |
Ampacity In Duct N/A 395 Amps |
Fairfield Fairfield/Asset/TRIPLEX-URD.jpg |
Phase Conductor Size/7mÊÓƵ N/A 750 |
Phase Conductor Stranding N/A 61/w |
Phase Conductor Insulation Thickness N/A 110 mls |
Neutral Size 7mÊÓƵ N/A 500 | Neutral Stranding N/A 37/w | Neutral Insulation Thickness N/A 95 mls |
Single Phase Conductor N/A 1.188 Inches |
Outside Diameter N/A 2.0860 Inches |
Weight (lb/1000 ft) N/A 2304 Lbs |
Ampacity Direct Burial N/A 615 Amps |
Ampacity In Duct N/A 525 Amps |